Datasheet | 2046-60-C2FLF |
File Size | 168.9 KB |
Total Pages | 3 |
Manufacturer | Bourns |
Website | http://www.bourns.com/ |
Total Parts | This datasheet covers 27 part numbers |
Associated Parts | 2046-60-C2FLF, 2046-47-C2FLF, 2046-42-C2FLF, 2046-40-C2FLF, 2046-35-C2FLF, 2046-25-C2FLF, 2046-23-C2FLF, 2046-14-C2FLF, 2046-09-C2FLF, 2046-60-C2LF, 2046-47-C2LF, 2046-40-C2LF, 2046-25-C2LF, 2046-14-C2LF, 2046-09-C2LF, 2046-60-ALF, 2046-47-ALF, 2046-42-ALF, 2046-35-ALF, 2046-25-ALF, 2046-14-ALF, 2046-40-ALF, 2046-23-ALF, 2046-09-ALF, 2046-23-C2LF, 2046-42-C2LF, 2046-35-C2LF |
Description | GDT 600V 20% 10KA T/H FAIL SHORT, GDT 470V 20% 10KA T/H FAIL SHORT, GDT 420V 20% 10KA T/H FAIL SHORT, GDT 400V 20% 10KA T/H FAIL SHORT, GDT 350V 20% 10KA T/H FAIL SHORT |
2046-60-C2FLF - Bourns



The Products You May Be Interested In
![]() |
2046-60-C2FLF | Bourns | GDT 600V 20% 10KA T/H FAIL SHORT | 160 More on Order |
![]() |
2046-47-C2FLF | Bourns | GDT 470V 20% 10KA T/H FAIL SHORT | 443 More on Order |
![]() |
2046-42-C2FLF | Bourns | GDT 420V 20% 10KA T/H FAIL SHORT | 173 More on Order |
![]() |
2046-40-C2FLF | Bourns | GDT 400V 20% 10KA T/H FAIL SHORT | 490 More on Order |
![]() |
2046-35-C2FLF | Bourns | GDT 350V 20% 10KA T/H FAIL SHORT | 153 More on Order |
![]() |
2046-25-C2FLF | Bourns | GDT 250V 20% 10KA T/H FAIL SHORT | 296 More on Order |
![]() |
2046-23-C2FLF | Bourns | GDT 230V 20% 10KA T/H FAIL SHORT | 208 More on Order |
![]() |
2046-14-C2FLF | Bourns | GDT 145V 20% 10KA T/H FAIL SHORT | 484 More on Order |
![]() |
2046-09-C2FLF | Bourns | GDT 90V 20% 10KA T/H FAIL SHORT | 147 More on Order |
![]() |
2046-60-C2LF | Bourns | GDT 600V 20% 10KA THROUGH HOLE | 417 More on Order |
![]() |
2046-47-C2LF | Bourns | GDT 470V 20% 10KA THROUGH HOLE | 389 More on Order |
![]() |
2046-40-C2LF | Bourns | GDT 400V 20% 10KA THROUGH HOLE | 101 More on Order |
URL Link
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 600V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short Yes Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 470V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short Yes Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 420V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short Yes Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 400V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short Yes Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 350V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short Yes Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 250V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short Yes Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 230V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short Yes Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 145V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short Yes Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 90V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short Yes Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 600V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short No Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 470V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short No Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Manufacturer Bourns Inc. Series 2046 Voltage - DC Spark Over (Nom) 400V Impulse Discharge Current (8/20µs) 10000A (10kA) Tolerance ±20% Number of Poles 3 Fail Short No Mounting Type Through Hole Package / Case Axial Cylinder, 3 Lead (Radial Bend) |