Datasheet | AMI-26-30-6 |
File Size | 676.65 KB |
Total Pages | 3 |
Manufacturer | Altran Magnetics |
Website | |
Total Parts | This datasheet covers 21 part numbers |
Associated Parts | AMI-26-30-6, AMI-26-20-6, AMI-26-20-1, AMI-26B-16-1, AMI-26-16-1, AMI-26A-12-1, AMI-26-12-1, AMI-26-10-3, AMI-26B-10-1, AMI-26-10-1, AMI-26B-3-1, AMI-26A-3-1, AMI-26-3-1, AMI-26-6-3, AMI-26-3-3, AMI-26B-6-1, AMI-26A-6-1, AMI-26-6-1, AMI-26-1-3, AMI-26B-1-1, AMI-26-1-1 |
Description | LINE FILTER 250VAC 30A CHASS MNT, LINE FILTER 250VAC 20A CHASS MNT, LINE FILTER 250VAC 20A CHASS MNT, LINE FILTER 250VAC 16A CHASS MNT, LINE FILTER 250VAC 16A CHASS MNT |
AMI-26-30-6 - Altran Magnetics
The Products You May Be Interested In
AMI-26-30-6 | Altran Magnetics | LINE FILTER 250VAC 30A CHASS MNT | 420 More on Order |
|
AMI-26-20-6 | Altran Magnetics | LINE FILTER 250VAC 20A CHASS MNT | 490 More on Order |
|
AMI-26-20-1 | Altran Magnetics | LINE FILTER 250VAC 20A CHASS MNT | 274 More on Order |
|
AMI-26B-16-1 | Altran Magnetics | LINE FILTER 250VAC 16A CHASS MNT | 409 More on Order |
|
AMI-26-16-1 | Altran Magnetics | LINE FILTER 250VAC 16A CHASS MNT | 381 More on Order |
|
AMI-26A-12-1 | Altran Magnetics | LINE FILTER 250VAC 12A CHASS MNT | 315 More on Order |
|
AMI-26-12-1 | Altran Magnetics | LINE FILTER 250VAC 12A CHASS MNT | 477 More on Order |
|
AMI-26-10-3 | Altran Magnetics | LINE FILTER 250VAC 10A CHASS MNT | 430 More on Order |
|
AMI-26B-10-1 | Altran Magnetics | LINE FILTER 250VAC 10A CHASS MNT | 448 More on Order |
|
AMI-26-10-1 | Altran Magnetics | LINE FILTER 250VAC 10A CHASS MNT | 111 More on Order |
|
AMI-26B-3-1 | Altran Magnetics | LINE FILTER 250VAC 3A CHASS MNT | 415 More on Order |
|
AMI-26A-3-1 | Altran Magnetics | LINE FILTER 250VAC 3A CHASS MNT | 318 More on Order |
URL Link
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 30A Frequency - Operating DC ~ 400Hz Applications General Purpose Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style Threaded Post (M4) Inductance 1.2mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 20A Frequency - Operating DC ~ 400Hz Applications General Purpose Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style - Inductance 1.2mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 20A Frequency - Operating DC ~ 400Hz Applications General Purpose Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style - Inductance 1.2mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 16A Frequency - Operating DC ~ 400Hz Applications Medical Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style Quick Connect Inductance 1.3mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 16A Frequency - Operating DC ~ 400Hz Applications General Purpose Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style Quick Connect Inductance 1.3mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 12A Frequency - Operating DC ~ 400Hz Applications Safety Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style Quick Connect Inductance 1.16mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 12A Frequency - Operating DC ~ 400Hz Applications General Purpose Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style Quick Connect Inductance 1.16mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 10A Frequency - Operating DC ~ 400Hz Applications General Purpose Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style Quick Connect Inductance 1.6mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 10A Frequency - Operating DC ~ 400Hz Applications Medical Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style Quick Connect Inductance 1.6mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 10A Frequency - Operating DC ~ 400Hz Applications General Purpose Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style Quick Connect Inductance 1.6mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 3A Frequency - Operating DC ~ 400Hz Applications Medical Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style Quick Connect Inductance 5mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Two Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 3A Frequency - Operating DC ~ 400Hz Applications Safety Approvals CE, cURus Operating Temperature -25°C ~ 100°C Mounting Type Chassis Mount Termination Style Quick Connect Inductance 5mH |