Datasheet | E2C-EDA21 2M |
File Size | 3,174.5 KB |
Total Pages | 17 |
Manufacturer | Omron Automation and Safety |
Website | |
Total Parts | This datasheet covers 10 part numbers |
Associated Parts | E2C-EDA21 2M, E2C-EDA11 2M, E2C-EDA41 2M, E2C-EM02H, E2C-EM02-F, E2C-EM07M, E2C-ED01-F, E2C-ED02-F, E2C-ED02, E2C-ED01 |
Description | SMART PROX SENSOR, AMP UNIT NPN FOR E2C PROX SENS, AMP UNIT PNP FOR E2C PROX SENS, SENSOR PROX INDUCT 2MM IP60 CYL, SENSOR PROX INDUCTIVE 2MM CYLIND |
E2C-EDA21 2M - Omron Automation and Safety
The Products You May Be Interested In
E2C-EDA21 2M | Omron Automation and Safety | SMART PROX SENSOR | 309 More on Order |
|
E2C-EDA11 2M | Omron Automation and Safety | AMP UNIT NPN FOR E2C PROX SENS | 427 More on Order |
|
E2C-EDA41 2M | Omron Automation and Safety | AMP UNIT PNP FOR E2C PROX SENS | 132 More on Order |
|
E2C-EM02H | Omron Automation and Safety | SENSOR PROX INDUCT 2MM IP60 CYL | 379 More on Order |
|
E2C-EM02-F | Omron Automation and Safety | SENSOR PROX INDUCTIVE 2MM CYLIND | 322 More on Order |
|
E2C-EM07M | Omron Automation and Safety | SENSOR PROX INDUCTIVE 7MM CYLIND | 144 More on Order |
|
E2C-ED01-F | Omron Automation and Safety | SENSOR PROX INDUCTIVE 1MM CYLIND | 195 More on Order |
|
E2C-ED02-F | Omron Automation and Safety | SENSOR PROX INDUCTIVE 2MM CYLIND | 274 More on Order |
|
E2C-ED02 | Omron Automation and Safety | SENSOR PROX INDUCTIVE 2MM CYLIND | 309 More on Order |
|
E2C-ED01 | Omron Automation and Safety | SENSOR PROX INDUCTIVE 1MM CYLIND | 358 More on Order |
URL Link
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E2C Amplifier Type Twin Output Voltage - Supply 12V ~ 24V Output Type NPN Current - Supply 45mA Operating Temperature -10°C ~ 55°C (TA) Mounting Type - |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E2C Amplifier Type Twin Output Voltage - Supply 12V ~ 24V Output Type NPN Current - Supply 45mA Operating Temperature -10°C ~ 55°C (TA) Mounting Type - |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E2C Amplifier Type Twin Output Voltage - Supply 12V ~ 24V Output Type PNP Current - Supply 45mA Operating Temperature -10°C ~ 55°C (TA) Mounting Type - |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E2C Sensor Type Inductive Sensing Distance 0.079" (2mm) Output Type Requires Amplifier Response Frequency - Shielding Shielded Material - Body Nickel-Plated Brass Voltage - Supply - Termination Style Cable Leads Operating Temperature -10°C ~ 200°C Ingress Protection IP60 Indicator No Indicator Package / Case Cylinder, Threaded |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E2C Sensor Type Inductive Sensing Distance 0.079" (2mm) Output Type Requires Amplifier Response Frequency - Shielding Shielded Material - Body Nickel-Plated Brass Voltage - Supply - Termination Style Cable Leads Operating Temperature -10°C ~ 60°C Ingress Protection IP67 Indicator No Indicator Package / Case Cylinder, Threaded |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E2C Sensor Type Inductive Sensing Distance 0.276" (7mm) Output Type Requires Amplifier Response Frequency - Shielding Unshielded Material - Body Nickel-Plated Brass Voltage - Supply - Termination Style Cable Leads Operating Temperature -10°C ~ 60°C Ingress Protection IP67 Indicator No Indicator Package / Case Cylinder, Threaded |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E2C Sensor Type Inductive Sensing Distance 0.039" (1mm) Output Type Requires Amplifier Response Frequency - Shielding Shielded Material - Body Stainless Steel Voltage - Supply - Termination Style Cable Leads Operating Temperature -10°C ~ 60°C Ingress Protection IP67 Indicator - Package / Case Cylinder |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E2C Sensor Type Inductive Sensing Distance 0.079" (2mm) Output Type Requires Amplifier Response Frequency - Shielding Shielded Material - Body Nickel-Plated Brass Voltage - Supply - Termination Style Cable Leads Operating Temperature -10°C ~ 60°C Ingress Protection IP67 Indicator No Indicator Package / Case Cylinder |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E2C Sensor Type Inductive Sensing Distance 0.079" (2mm) Output Type Requires Amplifier Response Frequency - Shielding Shielded Material - Body Nickel-Plated Brass Voltage - Supply - Termination Style Cable Leads Operating Temperature -10°C ~ 60°C Ingress Protection IP67 Indicator No Indicator Package / Case Cylinder |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E2C Sensor Type Inductive Sensing Distance 0.039" (1mm) Output Type Requires Amplifier Response Frequency - Shielding Shielded Material - Body Stainless Steel Voltage - Supply - Termination Style Cable Leads Operating Temperature -10°C ~ 60°C Ingress Protection IP67 Indicator No Indicator Package / Case Cylinder |