Datasheet | HAS 600-P |
File Size | 565.43 KB |
Total Pages | 3 |
Manufacturer | LEM |
Website | |
Total Parts | This datasheet covers 7 part numbers |
Associated Parts | HAS 600-P, HAS 500-P, HAS 400-P, HAS 200-P, HAS 100-P, HAS 50-P, HAS 300-P |
Description | SENSOR CURRENT HALL 600A AC/DC, SENSOR CURRENT HALL 500A AC/DC, SENSOR CURRENT HALL 400A AC/DC, SENSOR CURRENT HALL 200A AC/DC, SENSOR CURRENT HALL 100A AC/DC |
HAS 600-P - LEM



The Products You May Be Interested In
![]() |
HAS 600-P | LEM | SENSOR CURRENT HALL 600A AC/DC | 118 More on Order |
![]() |
HAS 500-P | LEM | SENSOR CURRENT HALL 500A AC/DC | 209 More on Order |
![]() |
HAS 400-P | LEM | SENSOR CURRENT HALL 400A AC/DC | 370 More on Order |
![]() |
HAS 200-P | LEM | SENSOR CURRENT HALL 200A AC/DC | 336 More on Order |
![]() |
HAS 100-P | LEM | SENSOR CURRENT HALL 100A AC/DC | 467 More on Order |
![]() |
HAS 50-P | LEM | SENSOR CURRENT HALL 50A AC/DC | 465 More on Order |
![]() |
HAS 300-P | LEM | SENSOR CURRENT HALL 300A AC/DC | 243 More on Order |
URL Link
Manufacturer LEM USA Inc. Series HAS For Measuring AC/DC Sensor Type Hall Effect, Open Loop Current - Sensing 600A Number of Channels 1 Output Ratiometric, Voltage Sensitivity - Frequency DC ~ 50kHz Linearity ±1% Accuracy ±1% Voltage - Supply ±15V Response Time 3µs Current - Supply (Max) 15mA Operating Temperature -10°C ~ 80°C Polarization Bidirectional Mounting Type Through Hole Package / Case Module Supplier Device Package - |
Manufacturer LEM USA Inc. Series HAS For Measuring AC/DC Sensor Type Hall Effect, Open Loop Current - Sensing 500A Number of Channels 1 Output Ratiometric, Voltage Sensitivity - Frequency DC ~ 50kHz Linearity ±1% Accuracy ±1% Voltage - Supply ±15V Response Time 3µs Current - Supply (Max) 15mA Operating Temperature -10°C ~ 80°C Polarization Bidirectional Mounting Type Through Hole Package / Case Module Supplier Device Package - |
Manufacturer LEM USA Inc. Series HAS For Measuring AC/DC Sensor Type Hall Effect, Open Loop Current - Sensing 400A Number of Channels 1 Output Ratiometric, Voltage Sensitivity - Frequency DC ~ 50kHz Linearity ±1% Accuracy ±1% Voltage - Supply ±15V Response Time 3µs Current - Supply (Max) 15mA Operating Temperature -10°C ~ 80°C Polarization Bidirectional Mounting Type Through Hole Package / Case Module Supplier Device Package - |
Manufacturer LEM USA Inc. Series HAS For Measuring AC/DC Sensor Type Hall Effect, Open Loop Current - Sensing 200A Number of Channels 1 Output Ratiometric, Voltage Sensitivity - Frequency DC ~ 50kHz Linearity ±1% Accuracy ±1% Voltage - Supply ±15V Response Time 3µs Current - Supply (Max) 15mA Operating Temperature -10°C ~ 80°C Polarization Bidirectional Mounting Type Through Hole Package / Case Module Supplier Device Package - |
Manufacturer LEM USA Inc. Series HAS For Measuring AC/DC Sensor Type Hall Effect, Open Loop Current - Sensing 100A Number of Channels 1 Output Ratiometric, Voltage Sensitivity - Frequency DC ~ 50kHz Linearity ±1% Accuracy ±1% Voltage - Supply ±15V Response Time 3µs Current - Supply (Max) 15mA Operating Temperature -10°C ~ 80°C Polarization Bidirectional Mounting Type Through Hole Package / Case Module Supplier Device Package - |
Manufacturer LEM USA Inc. Series HAS For Measuring AC/DC Sensor Type Hall Effect, Open Loop Current - Sensing 50A Number of Channels 1 Output Ratiometric, Voltage Sensitivity - Frequency DC ~ 50kHz Linearity ±1% Accuracy ±1% Voltage - Supply ±15V Response Time 3µs Current - Supply (Max) 15mA Operating Temperature -10°C ~ 80°C Polarization Bidirectional Mounting Type Through Hole Package / Case Module Supplier Device Package - |
Manufacturer LEM USA Inc. Series HAS For Measuring AC/DC Sensor Type Hall Effect, Open Loop Current - Sensing 300A Number of Channels 1 Output Ratiometric, Voltage Sensitivity - Frequency DC ~ 50kHz Linearity ±1% Accuracy ±1% Voltage - Supply ±15V Response Time 3µs Current - Supply (Max) 15mA Operating Temperature -10°C ~ 80°C Polarization Bidirectional Mounting Type Through Hole Package / Case Module Supplier Device Package - |