Datasheet | LPS-RK-600SP |
File Size | 1,051.66 KB |
Total Pages | 4 |
Manufacturer | Eaton - Bussmann Electrical Division |
Website | |
Total Parts | This datasheet covers 7 part numbers |
Associated Parts | LPS-RK-600SP, LPS-RK-400SP, LPS-RK-300SP, LPS-RK-200SP, LPS-RK-150SP, LPS-RK-125SP, LPS-RK-100SP |
Description | LOW-PEAK DUAL ELEMENT, LOW-PEAK DUAL ELEMENT, LOW-PEAK DUAL ELEMENT, LOW-PEAK DUAL ELEMENT, LOW-PEAK DUAL ELEMENT |
LPS-RK-600SP - Eaton - Bussmann Electrical Division
The Products You May Be Interested In
LPS-RK-600SP | Eaton - Bussmann Electrical Division | LOW-PEAK DUAL ELEMENT | 254 More on Order |
|
LPS-RK-400SP | Eaton - Bussmann Electrical Division | LOW-PEAK DUAL ELEMENT | 234 More on Order |
|
LPS-RK-300SP | Eaton - Bussmann Electrical Division | LOW-PEAK DUAL ELEMENT | 436 More on Order |
|
LPS-RK-200SP | Eaton - Bussmann Electrical Division | LOW-PEAK DUAL ELEMENT | 471 More on Order |
|
LPS-RK-150SP | Eaton - Bussmann Electrical Division | LOW-PEAK DUAL ELEMENT | 218 More on Order |
|
LPS-RK-125SP | Eaton - Bussmann Electrical Division | LOW-PEAK DUAL ELEMENT | 216 More on Order |
|
LPS-RK-100SP | Eaton - Bussmann Electrical Division | LOW-PEAK DUAL ELEMENT | 265 More on Order |
URL Link
Eaton - Bussmann Electrical Division Manufacturer Eaton - Bussmann Electrical Division Series Low-Peak™ LPS Fuse Type Cartridge Current Rating (Amps) 600A Voltage Rating - AC 600V Voltage Rating - DC 300V Response Time Slow Blow Applications Motor Protection, Transformer Protection Features - Class RK1 Approvals CE, CSA, UL Operating Temperature - Breaking Capacity @ Rated Voltage 300kA AC, 100kA DC Mounting Type Bolt Mount Package / Case Cylindrical, Blade Terminal (Bolt) Size / Dimension 2.880" Dia x 13.380" L (73.15mm x 339.85mm) |
Eaton - Bussmann Electrical Division Manufacturer Eaton - Bussmann Electrical Division Series Low-Peak™ LPS Fuse Type Cartridge Current Rating (Amps) 400A Voltage Rating - AC 600V Voltage Rating - DC 300V Response Time Slow Blow Applications Motor Protection, Transformer Protection Features - Class RK1 Approvals CE, CSA, UL Operating Temperature - Breaking Capacity @ Rated Voltage 300kA AC, 100kA DC Mounting Type Bolt Mount Package / Case Cylindrical, Blade Terminal (Bolt) Size / Dimension 2.360" Dia x 11.630" L (59.94mm x 295.40mm) |
Eaton - Bussmann Electrical Division Manufacturer Eaton - Bussmann Electrical Division Series Low-Peak™ LPS Fuse Type Cartridge Current Rating (Amps) 300A Voltage Rating - AC 600V Voltage Rating - DC 300V Response Time Slow Blow Applications Motor Protection, Transformer Protection Features - Class RK1 Approvals CE, CSA, UL Operating Temperature - Breaking Capacity @ Rated Voltage 300kA AC, 100kA DC Mounting Type Bolt Mount Package / Case Cylindrical, Blade Terminal (Bolt) Size / Dimension 2.360" Dia x 11.630" L (59.94mm x 295.40mm) |
Eaton - Bussmann Electrical Division Manufacturer Eaton - Bussmann Electrical Division Series Low-Peak™ LPS Fuse Type Cartridge Current Rating (Amps) 200A Voltage Rating - AC 600V Voltage Rating - DC 300V Response Time Slow Blow Applications Motor Protection, Transformer Protection Features - Class RK1 Approvals CE, CSA, UL Operating Temperature - Breaking Capacity @ Rated Voltage 300kA AC, 100kA DC Mounting Type Bolt Mount Package / Case Cylindrical, Blade Terminal (Bolt) Size / Dimension 1.610" Dia x 9.630" L (40.89mm x 244.60mm) |
Eaton - Bussmann Electrical Division Manufacturer Eaton - Bussmann Electrical Division Series Low-Peak™ LPS Fuse Type Cartridge Current Rating (Amps) 150A Voltage Rating - AC 600V Voltage Rating - DC 300V Response Time Slow Blow Applications Motor Protection, Transformer Protection Features - Class RK1 Approvals CE, CSA, UL Operating Temperature - Breaking Capacity @ Rated Voltage 300kA AC, 100kA DC Mounting Type Bolt Mount Package / Case Cylindrical, Blade Terminal (Bolt) Size / Dimension 1.610" Dia x 9.630" L (40.89mm x 244.60mm) |
Eaton - Bussmann Electrical Division Manufacturer Eaton - Bussmann Electrical Division Series Low-Peak™ LPS Fuse Type Cartridge Current Rating (Amps) 125A Voltage Rating - AC 600V Voltage Rating - DC 300V Response Time Slow Blow Applications Motor Protection, Transformer Protection Features - Class RK1 Approvals CE, CSA, UL Operating Temperature - Breaking Capacity @ Rated Voltage 300kA AC, 100kA DC Mounting Type Bolt Mount Package / Case Cylindrical, Blade Terminal (Bolt) Size / Dimension 1.610" Dia x 9.630" L (40.89mm x 244.60mm) |
Eaton - Bussmann Electrical Division Manufacturer Eaton - Bussmann Electrical Division Series Low-Peak™ LPS Fuse Type Cartridge Current Rating (Amps) 100A Voltage Rating - AC 600V Voltage Rating - DC 300V Response Time Slow Blow Applications Motor Protection, Transformer Protection Features - Class RK1 Approvals CE, CSA, UL Operating Temperature - Breaking Capacity @ Rated Voltage 300kA AC, 100kA DC Mounting Type Bolt Mount Package / Case Cylindrical, Blade Terminal (Bolt) Size / Dimension 1.110" Dia x 7.880" L (28.19mm x 200.15mm) |