![PKS607YN Cover](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0001.jpg)
Datasheet | PKS607YN |
File Size | 1,629.57 KB |
Total Pages | 24 |
Manufacturer | Power Integrations |
Website | |
Total Parts | This datasheet covers 12 part numbers |
Associated Parts | PKS607YN, PKS607FN, PKS606FN, PKS605FN, PKS604FN, PKS606YN, PKS605YN, PKS604YN, PKS606PN, PKS605PN, PKS604PN, PKS603PN |
Description | IC OFFLINE SWIT OTP OCP HV TO220, IC OFFLINE SWIT OTP OCP HV TO262, IC OFFLINE SWIT OTP OCP HV TO262, IC OFFLINE SWIT OTP OCP HV TO262, IC OFFLINE SWIT OTP OCP HV TO262 |
PKS607YN - Power Integrations
![PKS607YN Datasheet Page 1](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0001.jpg)
![PKS607YN Datasheet Page 2](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0002.jpg)
![PKS607YN Datasheet Page 3](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0003.jpg)
![PKS607YN Datasheet Page 4](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0004.jpg)
![PKS607YN Datasheet Page 5](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0005.jpg)
![PKS607YN Datasheet Page 6](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0006.jpg)
![PKS607YN Datasheet Page 7](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0007.jpg)
![PKS607YN Datasheet Page 8](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0008.jpg)
![PKS607YN Datasheet Page 9](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0009.jpg)
![PKS607YN Datasheet Page 10](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0010.jpg)
![PKS607YN Datasheet Page 11](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0011.jpg)
![PKS607YN Datasheet Page 12](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0012.jpg)
![PKS607YN Datasheet Page 13](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0013.jpg)
![PKS607YN Datasheet Page 14](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0014.jpg)
![PKS607YN Datasheet Page 15](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0015.jpg)
![PKS607YN Datasheet Page 16](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0016.jpg)
![PKS607YN Datasheet Page 17](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0017.jpg)
![PKS607YN Datasheet Page 18](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0018.jpg)
![PKS607YN Datasheet Page 19](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0019.jpg)
![PKS607YN Datasheet Page 20](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0020.jpg)
![PKS607YN Datasheet Page 21](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0021.jpg)
![PKS607YN Datasheet Page 22](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0022.jpg)
![PKS607YN Datasheet Page 23](http://media.oemstron.com/oemstron/datasheet/sm/pks607yn-0023.jpg)
The Products You May Be Interested In
![]() |
PKS607YN | Power Integrations | IC OFFLINE SWIT OTP OCP HV TO220 | 412 More on Order |
![]() |
PKS607FN | Power Integrations | IC OFFLINE SWIT OTP OCP HV TO262 | 184 More on Order |
![]() |
PKS606FN | Power Integrations | IC OFFLINE SWIT OTP OCP HV TO262 | 428 More on Order |
![]() |
PKS605FN | Power Integrations | IC OFFLINE SWIT OTP OCP HV TO262 | 327 More on Order |
![]() |
PKS604FN | Power Integrations | IC OFFLINE SWIT OTP OCP HV TO262 | 171 More on Order |
![]() |
PKS606YN | Power Integrations | IC OFFLINE SWIT OTP OCP HV TO220 | 450 More on Order |
![]() |
PKS605YN | Power Integrations | IC OFFLINE SWIT OTP OCP HV TO220 | 428 More on Order |
![]() |
PKS604YN | Power Integrations | IC OFFLINE SWIT OTP OCP HV TO220 | 485 More on Order |
![]() |
PKS606PN | Power Integrations | IC OFFLINE SWIT OTP OCP HV 8DIP | 247 More on Order |
![]() |
PKS605PN | Power Integrations | IC OFFLINE SWIT OTP OCP HV 8DIP | 418 More on Order |
![]() |
PKS604PN | Power Integrations | IC OFFLINE SWIT OTP OCP HV 8DIP | 144 More on Order |
![]() |
PKS603PN | Power Integrations | IC OFFLINE SWIT OTP OCP HV 8DIP | 464 More on Order |
URL Link
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 126W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case TO-220-7 (Formed Leads), 6 Leads Supplier Device Package TO-220-7C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 126W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case TO-262-7 (Formed Leads), 6 Leads Supplier Device Package TO-262-7C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 117W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case TO-262-7 (Formed Leads), 6 Leads Supplier Device Package TO-262-7C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 79W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case TO-262-7 (Formed Leads), 6 Leads Supplier Device Package TO-262-7C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 56W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case TO-262-7 (Formed Leads), 6 Leads Supplier Device Package TO-262-7C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 117W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case TO-220-7 (Formed Leads), 6 Leads Supplier Device Package TO-220-7C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 79W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case TO-220-7 (Formed Leads), 6 Leads Supplier Device Package TO-220-7C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 56W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case TO-220-7 (Formed Leads), 6 Leads Supplier Device Package TO-220-7C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 66W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case 8-DIP (0.300", 7.62mm), 7 Leads Supplier Device Package DIP-8C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 60W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case 8-DIP (0.300", 7.62mm), 7 Leads Supplier Device Package DIP-8C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 56W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case 8-DIP (0.300", 7.62mm), 7 Leads Supplier Device Package DIP-8C Mounting Type Through Hole |
Manufacturer Power Integrations Series PeakSwitch® Output Isolation Isolated Internal Switch(s) Yes Voltage - Breakdown 700V Topology Flyback Voltage - Start Up - Voltage - Supply (Vcc/Vdd) - Duty Cycle 65% Frequency - Switching 277kHz Power (Watts) 32W Fault Protection Current Limiting, Over Load, Over Temperature Control Features EN Operating Temperature -40°C ~ 150°C (TJ) Package / Case 8-DIP (0.300", 7.62mm), 7 Leads Supplier Device Package DIP-8C Mounting Type Through Hole |