Datasheet | THM 3-4823 |
File Size | 956.61 KB |
Total Pages | 5 |
Manufacturer | Traco Power |
Website | |
Total Parts | This datasheet covers 32 part numbers |
Associated Parts | THM 3-4823, THM 3-4821, THM 3-0523, THM 3-0521, THM 3-2423, THM 3-2421, THM 3-1223, THM 3-1221, THM 3-4815, THM 3-4813, THM 3-4810, THM 3-0515, THM 3-0513, THM 3-0510, THM 3-2413, THM 3-2410, THM 3-1215, THM 3-1213, THM 3-1210, THM 3-2415, THM 3-4822, THM 3-0522, THM 3-1222, THM 3-2422, THM 3-4812, THM 3-4811, THM 3-0512, THM 3-0511, THM 3-2412, THM 3-1211, THM 3-2411, THM 3-1212 |
Description | DC DC CONVERTER +/-15V 3W, DC DC CONVERTER +/-5V 3W, DC DC CONVERTER +/-15V 3W, DC DC CONVERTER +/-5V 3W, DC DC CONVERTER +/-15V 3W |
THM 3-4823 - Traco Power
The Products You May Be Interested In
THM 3-4823 | Traco Power | DC DC CONVERTER +/-15V 3W | 308 More on Order |
|
THM 3-4821 | Traco Power | DC DC CONVERTER +/-5V 3W | 411 More on Order |
|
THM 3-0523 | Traco Power | DC DC CONVERTER +/-15V 3W | 406 More on Order |
|
THM 3-0521 | Traco Power | DC DC CONVERTER +/-5V 3W | 148 More on Order |
|
THM 3-2423 | Traco Power | DC DC CONVERTER +/-15V 3W | 428 More on Order |
|
THM 3-2421 | Traco Power | DC DC CONVERTER +/-5V 3W | 233 More on Order |
|
THM 3-1223 | Traco Power | DC DC CONVERTER +/-15V 3W | 232 More on Order |
|
THM 3-1221 | Traco Power | DC DC CONVERTER +/-5V 3W | 263 More on Order |
|
THM 3-4815 | Traco Power | DC DC CONVERTER 24V 3W | 210 More on Order |
|
THM 3-4813 | Traco Power | DC DC CONVERTER 15V 3W | 476 More on Order |
|
THM 3-4810 | Traco Power | DC DC CONVERTER 3.3V 3.3W | 275 More on Order |
|
THM 3-0515 | Traco Power | DC DC CONVERTER 24V 3W | 144 More on Order |
URL Link
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 18V Voltage - Input (Max) 75V Voltage - Output 1 15V Voltage - Output 2 -15V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 100mA, 100mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 86% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 18V Voltage - Input (Max) 75V Voltage - Output 1 5V Voltage - Output 2 -5V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 300mA, 300mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 83% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 4.5V Voltage - Input (Max) 9V Voltage - Output 1 15V Voltage - Output 2 -15V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 100mA, 100mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 86% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 4.5V Voltage - Input (Max) 9V Voltage - Output 1 5V Voltage - Output 2 -5V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 300mA, 300mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 83% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 9V Voltage - Input (Max) 36V Voltage - Output 1 15V Voltage - Output 2 -15V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 100mA, 100mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 86% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 9V Voltage - Input (Max) 36V Voltage - Output 1 5V Voltage - Output 2 -5V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 300mA, 300mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 83% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 9V Voltage - Input (Max) 18V Voltage - Output 1 15V Voltage - Output 2 -15V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 100mA, 100mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 86.5% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 9V Voltage - Input (Max) 18V Voltage - Output 1 5V Voltage - Output 2 -5V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 300mA, 300mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 83.5% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 1 Voltage - Input (Min) 18V Voltage - Input (Max) 75V Voltage - Output 1 24V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 125mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 86.5% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 1 Voltage - Input (Min) 18V Voltage - Input (Max) 75V Voltage - Output 1 15V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 200mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 86.5% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 1 Voltage - Input (Min) 18V Voltage - Input (Max) 75V Voltage - Output 1 3.3V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 1A Power (Watts) 3.3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 81% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 3 (3W) Type Isolated Module Number of Outputs 1 Voltage - Input (Min) 4.5V Voltage - Input (Max) 9V Voltage - Output 1 24V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 125mA Power (Watts) 3W Voltage - Isolation 5kV Applications Medical Features OCP, OVP, SCP Operating Temperature -40°C ~ 90°C Efficiency 85.5% Mounting Type Through Hole Package / Case 24-DIP Module, 6 Leads Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Supplier Device Package - Control Features |