![XMS5006G Cover](http://media.oemstron.com/oemstron/datasheet/sm/xms5006g-0001.jpg)
Datasheet | XMS5006G |
File Size | 1,338.12 KB |
Total Pages | 6 |
Manufacturer | TDK-Lambda |
Website | http://www.tdk-lambda.com |
Total Parts | This datasheet covers 24 part numbers |
Associated Parts | XMS5006G, XMS500T0, XMS500LV, XMS500DP, XMS5004F, XMS500RY, XMS500JT, XMS500BN, XMS50024, XMS500NW, XMS500G8, XMS5008H, XMS5005Y, XMS500SG, XMS500KB, XMS500C6, XMS5003X, XMS50091, XMS500PX, XMS500HS, XMS5001M, XMS500MC, XMS500FR, XMS50070 |
Description | AC/DC CONVERTER 12V 500W, AC/DC CONVERTER 48V 500W, AC/DC CONVERTER 36V 500W, AC/DC CONVERTER 24V 500W, AC/DC CONVERTER 12V 500W |
XMS5006G - TDK-Lambda
![XMS5006G Datasheet Page 1](http://media.oemstron.com/oemstron/datasheet/sm/xms5006g-0001.jpg)
![XMS5006G Datasheet Page 2](http://media.oemstron.com/oemstron/datasheet/sm/xms5006g-0002.jpg)
![XMS5006G Datasheet Page 3](http://media.oemstron.com/oemstron/datasheet/sm/xms5006g-0003.jpg)
![XMS5006G Datasheet Page 4](http://media.oemstron.com/oemstron/datasheet/sm/xms5006g-0004.jpg)
![XMS5006G Datasheet Page 5](http://media.oemstron.com/oemstron/datasheet/sm/xms5006g-0005.jpg)
![XMS5006G Datasheet Page 6](http://media.oemstron.com/oemstron/datasheet/sm/xms5006g-0006.jpg)
The Products You May Be Interested In
![]() |
XMS5006G | TDK-Lambda | AC/DC CONVERTER 12V 500W | 284 More on Order |
![]() |
XMS500T0 | TDK-Lambda | AC/DC CONVERTER 48V 500W | 303 More on Order |
![]() |
XMS500LV | TDK-Lambda | AC/DC CONVERTER 36V 500W | 219 More on Order |
![]() |
XMS500DP | TDK-Lambda | AC/DC CONVERTER 24V 500W | 467 More on Order |
![]() |
XMS5004F | TDK-Lambda | AC/DC CONVERTER 12V 500W | 309 More on Order |
![]() |
XMS500RY | TDK-Lambda | AC/DC CONVERTER 48V 500W | 248 More on Order |
![]() |
XMS500JT | TDK-Lambda | AC/DC CONVERTER 36V 500W | 362 More on Order |
![]() |
XMS500BN | TDK-Lambda | AC/DC CONVERTER 24V 500W | 487 More on Order |
![]() |
XMS50024 | TDK-Lambda | AC/DC CONVERTER 12V 500W | 413 More on Order |
![]() |
XMS500NW | TDK-Lambda | AC/DC CONVERTER 48V 500W | 303 More on Order |
![]() |
XMS500G8 | TDK-Lambda | AC/DC CONVERTER 36V 500W | 431 More on Order |
![]() |
XMS5008H | TDK-Lambda | AC/DC CONVERTER 24V 500W | 301 More on Order |
URL Link
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Enclosed Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 12V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 41.6A Power (Watts) 500W Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.09" L x 4.21" W x 1.85" H (180.0mm x 107.0mm x 47.0mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Enclosed Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 48V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 10.4A Power (Watts) 500W Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.09" L x 4.21" W x 1.85" H (180.0mm x 107.0mm x 47.0mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Enclosed Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 36V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 13.8A Power (Watts) 500W Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.09" L x 4.21" W x 1.85" H (180.0mm x 107.0mm x 47.0mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Enclosed Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 24V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 20.8A Power (Watts) 500W Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.09" L x 4.21" W x 1.85" H (180.0mm x 107.0mm x 47.0mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Open Frame Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 12V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 41.6A Power (Watts) 250W (500W Forced Air) Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.09" L x 4.21" W x 1.56" H (180.0mm x 107.0mm x 39.5mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Open Frame Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 48V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 10.4A Power (Watts) 250W (500W Forced Air) Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.09" L x 4.21" W x 1.56" H (180.0mm x 107.0mm x 39.5mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Open Frame Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 36V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 13.8A Power (Watts) 250W (500W Forced Air) Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.09" L x 4.21" W x 1.56" H (180.0mm x 107.0mm x 39.5mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Open Frame Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 24V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 20.8A Power (Watts) 250W (500W Forced Air) Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.09" L x 4.21" W x 1.56" H (180.0mm x 107.0mm x 39.5mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Open Frame Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 12V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 41.6A Power (Watts) 250W (500W Forced Air) Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.10" L x 4.00" W x 1.46" H (180.0mm x 102.0mm x 37.0mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Open Frame Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 48V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 10.4A Power (Watts) 250W (500W Forced Air) Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.10" L x 4.00" W x 1.46" H (180.0mm x 102.0mm x 37.0mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Open Frame Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 36V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 13.8A Power (Watts) 250W (500W Forced Air) Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.10" L x 4.00" W x 1.46" H (180.0mm x 102.0mm x 37.0mm) |
Manufacturer TDK-Lambda Americas Inc. Series XMS500 (500W) Type Open Frame Number of Outputs 1 Voltage - Input 90 ~ 264 VAC Voltage - Output 1 24V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 20.8A Power (Watts) 250W (500W Forced Air) Applications ITE (Commercial), Medical Voltage - Isolation 4kV Efficiency 92% Operating Temperature 0°C ~ 70°C (With Derating) Features Universal Input Mounting Type Chassis Mount Size / Dimension 7.10" L x 4.00" W x 1.46" H (180.0mm x 102.0mm x 37.0mm) |