Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Number of Poles | Actuator Type | Illumination | Illumination Voltage (Nominal) | Mounting Type | Approvals |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM 15A 250VAC 50VDC |
In Stock117 More on Order |
|
Series: TS |
Breaker Type: Thermal |
Current Rating (Amps): 15A |
Voltage Rating - AC: 250V |
Voltage Rating - DC: 50V |
Number of Poles: 1 |
Actuator Type: Push to Reset |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: Panel Mount |
Approvals: - |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM 20A 240VAC 28VDC |
In Stock389 More on Order |
|
Series: T12 |
Breaker Type: Thermal |
Current Rating (Amps): 20A |
Voltage Rating - AC: 240V |
Voltage Rating - DC: 28V |
Number of Poles: 1 |
Actuator Type: Push-Push |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: Panel Mount |
Approvals: - |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM 20A 240VAC 28VDC |
In Stock125 More on Order |
|
Series: T12 |
Breaker Type: Thermal |
Current Rating (Amps): 20A |
Voltage Rating - AC: 240V |
Voltage Rating - DC: 28V |
Number of Poles: 1 |
Actuator Type: Push to Reset |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: Panel Mount |
Approvals: - |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR 50A 277VAC 65VDC |
In Stock428 More on Order |
|
Series: AS168X |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 50A |
Voltage Rating - AC: 277V |
Voltage Rating - DC: 65V |
Number of Poles: 1 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 1.5A 277V 65V |
In Stock180 More on Order |
|
Series: AS168X |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 1.5A |
Voltage Rating - AC: 277V |
Voltage Rating - DC: 65V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR 25A 277VAC 65VDC |
In Stock125 More on Order |
|
Series: AS168X |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 25A |
Voltage Rating - AC: 277V |
Voltage Rating - DC: 65V |
Number of Poles: 1 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR 25A 277VAC 65VDC |
In Stock251 More on Order |
|
Series: AS168X |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 25A |
Voltage Rating - AC: 277V |
Voltage Rating - DC: 65V |
Number of Poles: 1 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 1A 277V 65V |
In Stock306 More on Order |
|
Series: AS168X |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 1A |
Voltage Rating - AC: 277V |
Voltage Rating - DC: 65V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 27A 277V 65V |
In Stock260 More on Order |
|
Series: AS168XAC1 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 27A |
Voltage Rating - AC: 277V |
Voltage Rating - DC: 65V |
Number of Poles: 1 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 3A 480V 65V |
In Stock192 More on Order |
|
Series: AS168XAC2 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 3A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 5A 480V 65V |
In Stock107 More on Order |
|
Series: AS168XAC2 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 5A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 16A 480V 65V |
In Stock226 More on Order |
|
Series: AS168XAC2 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 16A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 25A 180 VDC |
In Stock296 More on Order |
|
Series: AS168XDC1 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 25A |
Voltage Rating - AC: - |
Voltage Rating - DC: 180V |
Number of Poles: 1 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 15A 480V 65V |
In Stock306 More on Order |
|
Series: AS168XAC3 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 15A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 3 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 25A 360 VDC |
In Stock312 More on Order |
|
Series: AS168XDC2 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 25A |
Voltage Rating - AC: - |
Voltage Rating - DC: 360V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 16A 480V 65V |
In Stock380 More on Order |
|
Series: AS168XAC3 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 16A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 3 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 20A 480V 65V |
In Stock275 More on Order |
|
Series: AS168XAC3 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 20A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 3 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 16A 480V 65V |
In Stock287 More on Order |
|
Series: AS168XAC3 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 16A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 3 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 15A 180 VDC |
In Stock455 More on Order |
|
Series: AS168XDC1 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 15A |
Voltage Rating - AC: - |
Voltage Rating - DC: 180V |
Number of Poles: 1 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 20A 480V 65V |
In Stock421 More on Order |
|
Series: AS168XAC3 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 20A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 3 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRMMAG 3A 277VAC 65VDC |
In Stock355 More on Order |
|
Series: AS168X |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 3A |
Voltage Rating - AC: 277V |
Voltage Rating - DC: 65V |
Number of Poles: 1 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: - |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 18A 480V 65V |
In Stock246 More on Order |
|
Series: AS168XAC2 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 18A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 23A 480V 65V |
In Stock313 More on Order |
|
Series: AS168XAC3 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 23A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 3 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 50MA 277V 65V |
In Stock487 More on Order |
|
Series: AS168XAC1 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 500mA |
Voltage Rating - AC: 277V |
Voltage Rating - DC: 65V |
Number of Poles: 1 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 15A 480V 65V |
In Stock334 More on Order |
|
Series: AS168XAC2 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 15A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 1A 360 VDC |
In Stock242 More on Order |
|
Series: AS168XDC2 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 1A |
Voltage Rating - AC: - |
Voltage Rating - DC: 360V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 50A 360 VDC |
In Stock236 More on Order |
|
Series: AS168XDC2 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 50A |
Voltage Rating - AC: - |
Voltage Rating - DC: 360V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 20A 480V 65V |
In Stock341 More on Order |
|
Series: AS168XAC2 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 20A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 16A 480V 65V |
In Stock117 More on Order |
|
Series: AS168XAC3 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 16A |
Voltage Rating - AC: 480V |
Voltage Rating - DC: 65V |
Number of Poles: 3 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
![]() |
Schurter |
Circuit Protection - Circuit Breakers CIR BRKR THRM MAG 30A 360 VDC |
In Stock402 More on Order |
|
Series: AS168XDC2 |
Breaker Type: Thermal Magnetic |
Current Rating (Amps): 30A |
Voltage Rating - AC: - |
Voltage Rating - DC: 360V |
Number of Poles: 2 |
Actuator Type: Lever |
Illumination: - |
Illumination Voltage (Nominal): - |
Mounting Type: DIN Rail |
Approvals: CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |