Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approvals | Operating Temperature | Breaking Capacity @ Rated Voltage | Mounting Type | Package / Case | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Amprobe |
Circuit Protection - Electrical, Specialty Fuses FUSE 11A 1KVAC |
In Stock209 More on Order |
|
Series: - |
Fuse Type: - |
Current Rating (Amps): 11A |
Voltage Rating - AC: 1kV |
Voltage Rating - DC: - |
Response Time: - |
Applications: Multi-Meters |
Features: - |
Class: - |
Approvals: - |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: - |
Mounting Type: - |
Package / Case: - |
Size / Dimension: - |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 10A 600VAC/300VDC |
In Stock299 More on Order |
|
Series: POWR-GARD® KLKR |
Fuse Type: Cartridge |
Current Rating (Amps): 10A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 300V |
Response Time: Fast Blow |
Applications: Electrical, Industrial |
Features: - |
Class: CC |
Approvals: CE, CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 200kA AC, 20kA DC |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.30mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 2A 600VAC/300VDC |
In Stock360 More on Order |
|
Series: POWR-GARD® KLKR |
Fuse Type: Cartridge |
Current Rating (Amps): 2A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 300V |
Response Time: Fast Blow |
Applications: Electrical, Industrial |
Features: - |
Class: CC |
Approvals: CE, CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 200kA AC, 20kA DC |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.30mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 20A 600VAC/300VDC |
In Stock471 More on Order |
|
Series: POWR-GARD® KLKR |
Fuse Type: Cartridge |
Current Rating (Amps): 20A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 300V |
Response Time: Fast Blow |
Applications: Electrical, Industrial |
Features: - |
Class: CC |
Approvals: CE, CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 200kA AC, 20kA DC |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.30mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 15A 1KVDC 5AG |
In Stock416 More on Order |
|
Series: POWR-GARD® SPF |
Fuse Type: Cartridge |
Current Rating (Amps): 15A |
Voltage Rating - AC: - |
Voltage Rating - DC: 1kV |
Response Time: Fast Blow |
Applications: Solar (Photovoltaic) |
Features: - |
Class: - |
Approvals: CE, CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 20kA |
Mounting Type: Through Hole |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 12A 600VAC/500VDC |
In Stock109 More on Order |
|
Series: POWR-GARD® KLK |
Fuse Type: Cartridge |
Current Rating (Amps): 12A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 500V |
Response Time: Fast Blow |
Applications: Electrical, Industrial |
Features: - |
Class: - |
Approvals: CE, CSA, QPL, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 100kA AC, 50kA DC |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 300MA 600VAC/VDC |
In Stock297 More on Order |
|
Series: POWR-GARD® KLKD |
Fuse Type: Cartridge |
Current Rating (Amps): 300mA |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 600V |
Response Time: Fast Blow |
Applications: Solar (Photovoltaic) |
Features: - |
Class: - |
Approvals: CE, CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 100kA AC, 50kA DC |
Mounting Type: Holder |
Package / Case: Cartridge, Non-Standard |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 4A 600VAC/VDC |
In Stock467 More on Order |
|
Series: POWR-GARD® KLKD |
Fuse Type: Cartridge |
Current Rating (Amps): 4A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 600V |
Response Time: Fast Blow |
Applications: Solar (Photovoltaic) |
Features: - |
Class: - |
Approvals: CE, CSA, UL, VDE |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 100kA AC, 50kA DC |
Mounting Type: Holder |
Package / Case: Cartridge, Non-Standard |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 500MA 600VAC/VDC |
In Stock238 More on Order |
|
Series: POWR-GARD® KLKD |
Fuse Type: Cartridge |
Current Rating (Amps): 500mA |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 600V |
Response Time: Fast Blow |
Applications: Solar (Photovoltaic) |
Features: - |
Class: - |
Approvals: CE, CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 100kA AC, 50kA DC |
Mounting Type: Holder |
Package / Case: Cartridge, Non-Standard |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 12A 600VAC/VDC |
In Stock494 More on Order |
|
Series: POWR-GARD® KLKD |
Fuse Type: Cartridge |
Current Rating (Amps): 12A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 600V |
Response Time: Fast Blow |
Applications: Solar (Photovoltaic) |
Features: - |
Class: - |
Approvals: CE, CSA, UL, VDE |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 100kA AC, 50kA DC |
Mounting Type: Holder |
Package / Case: Cartridge, Non-Standard |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 4A 500VAC/300VDC |
In Stock283 More on Order |
|
Series: POWR-GARD® FLQ |
Fuse Type: Cartridge |
Current Rating (Amps): 4A |
Voltage Rating - AC: 500V |
Voltage Rating - DC: 300V |
Response Time: Slow Blow |
Applications: Transformer Protection |
Features: - |
Class: - |
Approvals: CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 10kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 3A 500VAC/300VDC |
In Stock308 More on Order |
|
Series: POWR-GARD® FLQ |
Fuse Type: Cartridge |
Current Rating (Amps): 3A |
Voltage Rating - AC: 500V |
Voltage Rating - DC: 300V |
Response Time: Slow Blow |
Applications: Transformer Protection |
Features: - |
Class: - |
Approvals: CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 10kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 10A 500VAC/300VDC |
In Stock468 More on Order |
|
Series: POWR-GARD® FLQ |
Fuse Type: Cartridge |
Current Rating (Amps): 10A |
Voltage Rating - AC: 500V |
Voltage Rating - DC: 300V |
Response Time: Slow Blow |
Applications: Transformer Protection |
Features: - |
Class: - |
Approvals: CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 10kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 8A 500VAC/300VDC |
In Stock305 More on Order |
|
Series: POWR-GARD® FLQ |
Fuse Type: Cartridge |
Current Rating (Amps): 8A |
Voltage Rating - AC: 500V |
Voltage Rating - DC: 300V |
Response Time: Slow Blow |
Applications: Transformer Protection |
Features: - |
Class: - |
Approvals: CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 10kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 25A 500VAC/300VDC |
In Stock326 More on Order |
|
Series: POWR-GARD® FLQ |
Fuse Type: Cartridge |
Current Rating (Amps): 25A |
Voltage Rating - AC: 500V |
Voltage Rating - DC: 300V |
Response Time: Slow Blow |
Applications: Transformer Protection |
Features: - |
Class: - |
Approvals: CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 10kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 15A 500VAC/300VDC |
In Stock504 More on Order |
|
Series: POWR-GARD® FLQ |
Fuse Type: Cartridge |
Current Rating (Amps): 15A |
Voltage Rating - AC: 500V |
Voltage Rating - DC: 300V |
Response Time: Slow Blow |
Applications: Transformer Protection |
Features: - |
Class: - |
Approvals: CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 10kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 1A 500VAC/300VDC |
In Stock463 More on Order |
|
Series: POWR-GARD® FLQ |
Fuse Type: Cartridge |
Current Rating (Amps): 1A |
Voltage Rating - AC: 500V |
Voltage Rating - DC: 300V |
Response Time: Slow Blow |
Applications: Transformer Protection |
Features: - |
Class: - |
Approvals: CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 10kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 30A 600VAC/300VDC |
In Stock240 More on Order |
|
Series: POWR-GARD®, POWR-PRO® JTD |
Fuse Type: Cartridge |
Current Rating (Amps): 30A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 300V |
Response Time: Slow Blow |
Applications: Transformer Protection |
Features: - |
Class: J |
Approvals: CE, CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 200kA AC, 20kA DC |
Mounting Type: Holder |
Package / Case: Cartridge, Non-Standard |
Size / Dimension: 0.811" Dia x 2.252" L (20.60mm x 57.20mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CRTRDGE 400MA 500VAC/300VDC |
In Stock441 More on Order |
|
Series: POWR-GARD® FLQ |
Fuse Type: Cartridge |
Current Rating (Amps): 400mA |
Voltage Rating - AC: 500V |
Voltage Rating - DC: 300V |
Response Time: Slow Blow |
Applications: Transformer Protection |
Features: - |
Class: - |
Approvals: CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 10kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CRTRDGE 1.5A 500VAC/300VDC |
In Stock251 More on Order |
|
Series: POWR-GARD® FLQ |
Fuse Type: Cartridge |
Current Rating (Amps): 1.5A |
Voltage Rating - AC: 500V |
Voltage Rating - DC: 300V |
Response Time: Slow Blow |
Applications: Transformer Protection |
Features: - |
Class: - |
Approvals: CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 10kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE STRIP 150A 125VAC/48VDC |
In Stock232 More on Order |
|
Series: POWR-GARD® CNN |
Fuse Type: Fuse Strip |
Current Rating (Amps): 150A |
Voltage Rating - AC: 125V |
Voltage Rating - DC: 48V |
Response Time: Fast Blow |
Applications: Lift Trucks |
Features: Indicating |
Class: - |
Approvals: UR |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 2.5kA |
Mounting Type: Bolt Mount |
Package / Case: Cylindrical, Blade Terminal (Bolt) |
Size / Dimension: - |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 6A 600VAC/250VDC |
In Stock302 More on Order |
|
Series: POWR-GARD®, POWR-PRO® CCMR |
Fuse Type: Cartridge |
Current Rating (Amps): 6A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 250V |
Response Time: Slow Blow |
Applications: Motor Protection |
Features: - |
Class: CC |
Approvals: CE, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 300kA AC, 20kA DC |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.30mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 25A 600VAC/500VDC |
In Stock366 More on Order |
|
Series: POWR-GARD®, POWR-PRO® CCMR |
Fuse Type: Cartridge |
Current Rating (Amps): 25A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 500V |
Response Time: Slow Blow |
Applications: Motor Protection |
Features: - |
Class: CC |
Approvals: CE, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 200kA AC, 20kA DC |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.30mm x 38.10mm) |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE STRIP 250A 125VAC/48VDC |
In Stock318 More on Order |
|
Series: POWR-GARD® CNN |
Fuse Type: Fuse Strip |
Current Rating (Amps): 250A |
Voltage Rating - AC: 125V |
Voltage Rating - DC: 48V |
Response Time: Fast Blow |
Applications: Lift Trucks |
Features: Indicating |
Class: - |
Approvals: UR |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 2.5kA |
Mounting Type: Bolt Mount |
Package / Case: Cylindrical, Blade Terminal (Bolt) |
Size / Dimension: - |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 30A 600VAC |
In Stock259 More on Order |
|
Series: POWR-GARD® JLS |
Fuse Type: Cartridge |
Current Rating (Amps): 30A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: - |
Response Time: Fast Blow |
Applications: Electrical, Industrial |
Features: - |
Class: J |
Approvals: CE, CSA, QPL, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 200kA |
Mounting Type: Holder |
Package / Case: Cartridge, Non-Standard |
Size / Dimension: 0.811" Dia x 2.252" L (20.60mm x 57.20mm) |
|
|
Eaton - Bussmann Electrical Division |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 6A 600VAC/700VDC |
In Stock469 More on Order |
|
Series: FWC |
Fuse Type: Cartridge |
Current Rating (Amps): 6A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 700V |
Response Time: - |
Applications: Electrical, Industrial |
Features: - |
Class: - |
Approvals: CE, UR |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 200kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.30mm x 38.10mm) |
|
|
Fluke Electronics |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 15A 600VAC 5PK |
In Stock379 More on Order |
|
Series: - |
Fuse Type: Cartridge |
Current Rating (Amps): 15A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: - |
Response Time: Fast Blow |
Applications: Multi-Meters |
Features: - |
Class: - |
Approvals: - |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: - |
Mounting Type: Holder |
Package / Case: Cartridge, Non-Standard |
Size / Dimension: - |
|
|
Littelfuse |
Circuit Protection - Electrical, Specialty Fuses FUSE CRTRDGE 20A 600VAC/VDC 5AG |
In Stock454 More on Order |
|
Series: POWR-GARD® LA60Q |
Fuse Type: Cartridge |
Current Rating (Amps): 20A |
Voltage Rating - AC: 600V |
Voltage Rating - DC: 600V |
Response Time: Fast Blow |
Applications: Electrical, Industrial |
Features: - |
Class: - |
Approvals: UR |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 200kA AC, 100kA DC |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm) |
|
|
Eaton - Bussmann Electrical Division |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 500MA 600VAC 5AG |
In Stock350 More on Order |
|
Series: KTK |
Fuse Type: Cartridge |
Current Rating (Amps): 500mA |
Voltage Rating - AC: 600V |
Voltage Rating - DC: - |
Response Time: Fast Blow |
Applications: Electrical, Industrial |
Features: - |
Class: - |
Approvals: CSA, UL |
Operating Temperature: - |
Breaking Capacity @ Rated Voltage: 100kA |
Mounting Type: Holder |
Package / Case: 5AG, 10mm x 38.1mm |
Size / Dimension: 0.406" Dia x 1.500" L (10.30mm x 38.10mm) |
|
|
Eaton - Bussmann Electrical Division |
Circuit Protection - Electrical, Specialty Fuses FUSE CARTRIDGE 15A 1KVDC CYLINDR |
In Stock410 More on Order |
|
Series: PV |
Fuse Type: Cartridge |
Current Rating (Amps): 15A |
Voltage Rating - AC: - |
Voltage Rating - DC: 1kV |
Response Time: - |
Applications: Solar (Photovoltaic) |
Features: - |
Class: - |
Approvals: CCC, CSA, UL |
Operating Temperature: -40°C ~ 90°C |
Breaking Capacity @ Rated Voltage: 50kA |
Mounting Type: Bolt Mount |
Package / Case: Cylindrical, Blade Terminal (Bolt) |
Size / Dimension: 0.406" Dia x 2.319" L (10.30mm x 58.90mm) |