Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Voltage - DC Spark Over (Nom) | Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type | Package / Case |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 350V 20% 10KA FAIL SHORT |
In Stock239 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 350V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: Yes |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
![]() |
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 230V 20% 10KA THROUGH HOLE |
In Stock474 More on Order |
|
Series: T31-A230X |
Voltage - DC Spark Over (Nom): 230V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, 3 Lead (T-Shape) |
|
![]() |
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 350V 20KA THROUGH HOLE |
In Stock287 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 350V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: - |
Number of Poles: 3 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 250V 20% 20KA SURFACE MOUNT |
In Stock431 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 250V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Surface Mount |
Package / Case: Axial Cylinder, Radial SMT Bend |
|
![]() |
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 90V 5KA 3 POLE |
In Stock415 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 90V |
Impulse Discharge Current (8/20µs): 5000A (5kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT-PSW |
In Stock273 More on Order |
|
Series: GTC |
Voltage - DC Spark Over (Nom): 350V |
Impulse Discharge Current (8/20µs): 5000A (5kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: Yes |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 90V 10KA |
In Stock199 More on Order |
|
Series: SL1411A |
Voltage - DC Spark Over (Nom): 90V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 75V 10KA |
In Stock186 More on Order |
|
Series: SL1411A |
Voltage - DC Spark Over (Nom): 75V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 230V 10KA |
In Stock369 More on Order |
|
Series: SL1411A |
Voltage - DC Spark Over (Nom): 230V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 250V 10KA THROUGH HOLE |
In Stock285 More on Order |
|
Series: SL1411A |
Voltage - DC Spark Over (Nom): 250V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 250V 10KA |
In Stock240 More on Order |
|
Series: SL1411A |
Voltage - DC Spark Over (Nom): 250V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 350V 10KA |
In Stock490 More on Order |
|
Series: SL1411A |
Voltage - DC Spark Over (Nom): 350V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 470V 10KA THROUGH HOLE |
In Stock366 More on Order |
|
Series: SL1411A |
Voltage - DC Spark Over (Nom): 470V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 600V 10KA |
In Stock364 More on Order |
|
Series: SL1411A |
Voltage - DC Spark Over (Nom): 600V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 600V 5KA THROUGH HOLE |
In Stock158 More on Order |
|
Series: CG5 |
Voltage - DC Spark Over (Nom): 600V |
Impulse Discharge Current (8/20µs): 5000A (5kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 145V 5KA THROUGH HOLE |
In Stock319 More on Order |
|
Series: CG5 |
Voltage - DC Spark Over (Nom): 145V |
Impulse Discharge Current (8/20µs): 5000A (5kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 150V 20% 10KA THROUGH HOLE |
In Stock199 More on Order |
|
Series: GT |
Voltage - DC Spark Over (Nom): 150V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 230V 20% 10KA THROUGH HOLE |
In Stock223 More on Order |
|
Series: GT |
Voltage - DC Spark Over (Nom): 230V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 550V 5KA |
In Stock165 More on Order |
|
Series: CG5 |
Voltage - DC Spark Over (Nom): 550V |
Impulse Discharge Current (8/20µs): 5000A (5kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 470V 10KA |
In Stock127 More on Order |
|
Series: SL1411A |
Voltage - DC Spark Over (Nom): 470V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GTCR25-601L-R05 |
In Stock274 More on Order |
|
Series: * |
Voltage - DC Spark Over (Nom): - |
Impulse Discharge Current (8/20µs): - |
Tolerance: - |
Number of Poles: - |
Fail Short: - |
Mounting Type: - |
Package / Case: - |
|
![]() |
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) 3E FLAT GDT, HORIZONTAL, 150V |
In Stock417 More on Order |
|
Series: Flat® 2018 |
Voltage - DC Spark Over (Nom): 150V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: No |
Mounting Type: Surface Mount Horizontal |
Package / Case: Disc 8.00mm Tabbed SMD |
|
![]() |
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) 3E FLAT GDT, HORIZONTAL, 350V |
In Stock382 More on Order |
|
Series: Flat® 2018 |
Voltage - DC Spark Over (Nom): 350V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: No |
Mounting Type: Surface Mount Horizontal |
Package / Case: Disc 8.00mm Tabbed SMD |
|
![]() |
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) 3E FLAT GDT, HORIZONTAL, 500V |
In Stock350 More on Order |
|
Series: Flat® 2018 |
Voltage - DC Spark Over (Nom): 500V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: No |
Mounting Type: Surface Mount Horizontal |
Package / Case: Disc 8.00mm Tabbed SMD |
|
![]() |
Littelfuse |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 470V 20% 10KA T/H FAIL SHORT |
In Stock152 More on Order |
|
Series: GT |
Voltage - DC Spark Over (Nom): 470V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: Yes |
Mounting Type: Through Hole |
Package / Case: Radial Cylinder, 3 Lead |
|
![]() |
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 350V 10KA THROUGH HOLE |
In Stock291 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 350V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 3 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 90V 20% 10KA T/H FAIL SHORT |
In Stock147 More on Order |
|
Series: 2046 |
Voltage - DC Spark Over (Nom): 90V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: Yes |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 145V 20% 10KA T/H FAIL SHORT |
In Stock484 More on Order |
|
Series: 2046 |
Voltage - DC Spark Over (Nom): 145V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: Yes |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 230V 20% 10KA T/H FAIL SHORT |
In Stock208 More on Order |
|
Series: 2046 |
Voltage - DC Spark Over (Nom): 230V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: Yes |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 250V 20% 10KA T/H FAIL SHORT |
In Stock296 More on Order |
|
Series: 2046 |
Voltage - DC Spark Over (Nom): 250V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: ±20% |
Number of Poles: 3 |
Fail Short: Yes |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, 3 Lead (Radial Bend) |