Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Voltage - DC Spark Over (Nom) | Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type | Package / Case |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 470V 20% 40KA |
In Stock307 More on Order |
|
Series: 2061 |
Voltage - DC Spark Over (Nom): 470V |
Impulse Discharge Current (8/20µs): 40000A (40kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 600V 20% 40KA |
In Stock342 More on Order |
|
Series: 2061 |
Voltage - DC Spark Over (Nom): 600V |
Impulse Discharge Current (8/20µs): 40000A (40kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 250V 20% 60KA |
In Stock290 More on Order |
|
Series: 2063 |
Voltage - DC Spark Over (Nom): 250V |
Impulse Discharge Current (8/20µs): 60000A (60kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 420V 20% 60KA |
In Stock225 More on Order |
|
Series: 2063 |
Voltage - DC Spark Over (Nom): 420V |
Impulse Discharge Current (8/20µs): 60000A (60kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 700V 20% 60KA |
In Stock193 More on Order |
|
Series: 2063 |
Voltage - DC Spark Over (Nom): 700V |
Impulse Discharge Current (8/20µs): 60000A (60kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 230V 20% 60KA |
In Stock206 More on Order |
|
Series: 2063 |
Voltage - DC Spark Over (Nom): 230V |
Impulse Discharge Current (8/20µs): 60000A (60kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 350V 20% 60KA |
In Stock468 More on Order |
|
Series: 2063 |
Voltage - DC Spark Over (Nom): 350V |
Impulse Discharge Current (8/20µs): 60000A (60kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 470V 20% 60KA |
In Stock409 More on Order |
|
Series: 2063 |
Voltage - DC Spark Over (Nom): 470V |
Impulse Discharge Current (8/20µs): 60000A (60kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 600V 20% 60KA |
In Stock310 More on Order |
|
Series: 2063 |
Voltage - DC Spark Over (Nom): 600V |
Impulse Discharge Current (8/20µs): 60000A (60kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 800V 20% 60KA |
In Stock135 More on Order |
|
Series: 2063 |
Voltage - DC Spark Over (Nom): 800V |
Impulse Discharge Current (8/20µs): 60000A (60kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) 800V STACKED GDT-T/R |
In Stock462 More on Order |
|
Series: 2033 |
Voltage - DC Spark Over (Nom): 800V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±30% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead, 6 Terminal |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) 1400V STACKED GDT-T/R |
In Stock371 More on Order |
|
Series: 2033 |
Voltage - DC Spark Over (Nom): 1400V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±30% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead, 6 Terminal |
|
|
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) V13-H08X |
In Stock104 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): - |
Impulse Discharge Current (8/20µs): - |
Tolerance: - |
Number of Poles: - |
Fail Short: - |
Mounting Type: - |
Package / Case: - |
|
|
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 400V 20KA |
In Stock334 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 400V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 1200V 20% 20KA THROUGH HOLE |
In Stock297 More on Order |
|
Series: 2097 |
Voltage - DC Spark Over (Nom): 1200V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Chassis, Stud Mount |
Package / Case: Axial Cylinder |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 1400V 20% 20KA THROUGH HOLE |
In Stock398 More on Order |
|
Series: 2097 |
Voltage - DC Spark Over (Nom): 1400V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Chassis, Stud Mount |
Package / Case: Axial Cylinder |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 2000V 20% 20KA THROUGH HOLE |
In Stock448 More on Order |
|
Series: 2097 |
Voltage - DC Spark Over (Nom): 2000V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Chassis, Stud Mount |
Package / Case: Axial Cylinder |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 1000V 20% 20KA THROUGH HOLE |
In Stock402 More on Order |
|
Series: 2097 |
Voltage - DC Spark Over (Nom): 1000V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Chassis, Stud Mount |
Package / Case: Axial Cylinder |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 1600V 20% 20KA THROUGH HOLE |
In Stock228 More on Order |
|
Series: 2097 |
Voltage - DC Spark Over (Nom): 1600V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Chassis, Stud Mount |
Package / Case: Axial Cylinder |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 2200V 20% 20KA THROUGH HOLE |
In Stock406 More on Order |
|
Series: 2097 |
Voltage - DC Spark Over (Nom): 2200V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Chassis, Stud Mount |
Package / Case: Axial Cylinder |
|
|
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) V13-A500X |
In Stock344 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): - |
Impulse Discharge Current (8/20µs): - |
Tolerance: - |
Number of Poles: - |
Fail Short: - |
Mounting Type: - |
Package / Case: - |
|
|
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 1400V 20KA |
In Stock143 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 1400V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: User Defined |
Package / Case: Cylinder No Lead |
|
|
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 600V 20% 20KA THROUGH HOLE |
In Stock304 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 600V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, Radial Bend |
|
|
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 800V 20% 20KA THROUGH HOLE |
In Stock293 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 800V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder, Radial Bend |
|
|
Bourns |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 28V 10KA DIN RAIL 3 CLAMP |
In Stock231 More on Order |
|
Series: 1800 |
Voltage - DC Spark Over (Nom): 28V |
Impulse Discharge Current (8/20µs): 10000A (10kA) |
Tolerance: - |
Number of Poles: 3 |
Fail Short: No |
Mounting Type: DIN Rail |
Package / Case: Module, Plug-In Terminal Block |
|
|
TDK-EPCOS |
Circuit Protection - Gas Discharge Tube Arresters (GDT) H30-A800XP |
In Stock133 More on Order |
|
Series: EZ3-A90X |
Voltage - DC Spark Over (Nom): 90V |
Impulse Discharge Current (8/20µs): 5000A (5kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Through Hole |
Package / Case: Axial Cylinder |
|
|
Phoenix Contact |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT DIN RAIL TYPE2 ARRESTER PLUG |
In Stock341 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): - |
Impulse Discharge Current (8/20µs): - |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: DIN Rail |
Package / Case: Module |
|
|
Phoenix Contact |
Circuit Protection - Gas Discharge Tube Arresters (GDT) F-MS 80 ST |
In Stock276 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 240V |
Impulse Discharge Current (8/20µs): 40000A (40kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: - |
Mounting Type: Surface Mount |
Package / Case: Module, Plug-In Terminal Block |
|
|
Phoenix Contact |
Circuit Protection - Gas Discharge Tube Arresters (GDT) GDT 230V 20% 20KA DIN RAIL |
In Stock438 More on Order |
|
Series: - |
Voltage - DC Spark Over (Nom): 230V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: ±20% |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: DIN Rail |
Package / Case: Module, Terminal Block |
|
|
Eaton - Bussmann Electrical Division |
Circuit Protection - Gas Discharge Tube Arresters (GDT) REPLACEMENT MODULE GDT 255V MCOV |
In Stock398 More on Order |
|
Series: BP |
Voltage - DC Spark Over (Nom): 230V |
Impulse Discharge Current (8/20µs): 20000A (20kA) |
Tolerance: - |
Number of Poles: 2 |
Fail Short: No |
Mounting Type: Holder |
Package / Case: Module, Plug-In |