Maxim's single-channel integrated biopotential AFE and Bioimpedance (BioZ) + HR detection algorithms

Dec 31 2022 2022-12 Sensors Maxim Integrated
Article Cover
Maxim Integrated's MAX30001CVV+is an analog front-end (AFE) solution, including biopotential and bioimpedance (BioZ) for wearable applications. The solution is designed for fitness and clinical applications, and will extend battery life due to high performance and ultra-low power consumption. It is available in a 30 WLP and can operate in the temperature range of 0 ° C to+70 ° C.

     Maxim Integrated's MAX30001CWV+ is an analog front-end (AFE) solution that includes biopotential and Bioimpedance (BioZ) for wearable applications. The solution is designed specifically for fitness and clinical applications and will extend battery life due to high performance and ultra-low power consumption. It is available in a 30 WLP and can operate in a temperature range of 0°C to +70°C.

 

     The MAX30001 provides electrocardiogram (ECG) waveform, heart rate, and pacemaker edge detection. The device also includes a BioZ channel that measures respiration. Biopotential and BioZ channels provide high input impedance, low noise, high common-mode rejection ratio, programmable gain, various low-pass and high-pass filter options, and high-resolution analog-to-digital converters (ADCs). Both channels also feature ESD protection, EMI filtering, internal lead bias, DC lead disconnect detection, lead detection in standby mode, and extensive calibration voltage for built-in self-testing. Soft power enhanced sort ensures no large transient injection electrodes.

 

     Biopotential channels are DC-coupled, can handle large electrode voltage offsets, and have a fast recovery mode that allows quick recovery from overdrive conditions such as defibrillation and electrosurgery. Bioimpedance channels also include integrated programmable current drivers that work with regular electrodes and have the flexibility of two or four electrode measurements. It also has AC lead detection.

The Products You May Be Interested In

62054-P2S02 62054-P2S02 XFRMR TOROIDAL 15VA CHAS MOUNT 107

More on Order

62025-P2S02 62025-P2S02 XFRMR TOROIDAL 5VA CHAS MOUNT 218

More on Order

62021-P2S02 62021-P2S02 XFRMR TOROIDAL 5VA CHAS MOUNT 281

More on Order

62012-P2S02 62012-P2S02 XFRMR TOROIDAL 3.2VA CHAS MOUNT 178

More on Order

62073-P2S02 62073-P2S02 XFRMR TOROIDAL 35VA CHAS MOUNT 294

More on Order

70015K 70015K XFRMR TOROIDAL 3.2VA THRU HOLE 421

More on Order

62024-P2S02 62024-P2S02 XFRMR TOROIDAL 5VA CHAS MOUNT 268

More on Order

70064K 70064K XFRMR TOROIDAL 25VA THRU HOLE 2293

More on Order

MAX30110EWG+ MAX30110EWG+ IC SENSOR OXIMETER/HEARTRATE AFE 250

More on Order

MAX30112EWG+ MAX30112EWG+ IC SENSOR OXIMETER/HEARTRATE AFE 312

More on Order

MAX30103EFD+T MAX30103EFD+T INTEGRATED OPTICAL SENSOR 495

More on Order

MAX30103EFD+ MAX30103EFD+ INTEGRATED OPTICAL SENSOR 449

More on Order

MAX30100EFD+ MAX30100EFD+ IC SENSOR OXIMETER/HEARTRATE 391

More on Order

MAX30102EFD+T MAX30102EFD+T INTEGRATED OPTICAL SENSOR 219

More on Order

MAX30105EFD+T MAX30105EFD+T SENSOR OPTIC AIR QUAL 14-OESIP 176

More on Order

MAX30101EFD+T MAX30101EFD+T INTEGRATED OPTICAL SENSOR 100

More on Order

MAX30105EFD+ MAX30105EFD+ SENSOR OPTIC AIR QUAL 14-OESIP 1494

More on Order

MAX30112EWG+T MAX30112EWG+T INTEGRATED BIOSENSOR FOR MOBILE 426

More on Order

MAX30102EFD+ MAX30102EFD+ IC SENSOR OXIMETER/HEARTRATE 1387

More on Order

MAX30101EFD+ MAX30101EFD+ INTEGRATED OPTICAL SENSOR 5342

More on Order

MAX30208CLB+T MAX30208CLB+T IC TEMP SENSOR 452

More on Order

MAX30208CLB+ MAX30208CLB+ IC TEMP SENSOR 428

More on Order

MAX30205MTA+T MAX30205MTA+T SENSOR DIGITAL 0C-50C 8TDFN 444

More on Order

MAX30205MTA+ MAX30205MTA+ SENSOR DIGITAL 0C-50C 8TDFN 4535

More on Order